When to use it
Your life test ended with some units still running, or field data includes survivors: every unit has a time plus a status flag (1/True = failed at that time, 0/False = censored/suspended at that time). Use this instead of the uncensored Weibull fit whenever ANY unit did not fail: dropping or mis-coding survivors biases β and η, the classic reliability mistake.
When not to: Every single unit's exact failure time was observed with no survivors at all (the simpler uncensored Weibull fit is adequate and does not need the censoring machinery), fewer than 2 failures are observed (the MLE has too little information to estimate two parameters), or censoring is INFORMATIVE (units were pulled because they looked about to fail, rather than for a reason unrelated to imminent failure), in which case the non-informative-censoring assumption this method relies on is violated.
Step by step
Open it from the menu
Click Reliability & Survival in the menu bar; under Reliability choose Censored Weibull Reliability (Life-Data) Fit.
Fill in the form
Choose the columns: Time to failure or end of follow-up, Failed? (1 = failed, 0 = still running). The form lists only columns whose type fits each field.
Check the options
The options start at their defaults: Fix location at 0, Alpha. Change one only when your question needs it.
Run the analysis
Press Run analysis. The Result Card opens on its Results tab.
What to choose in the form
| Time to failure or end of follow-up Time required | One numeric column. Age at failure OR at censoring (numeric, > 0) |
|---|---|
| Failed? (1 = failed, 0 = still running) Status required | One categorical or numeric column. Event indicator: 1/True = failure observed, 0/False = right-censored (still running) |
| Fix location at 0 | Fix the location (threshold) at 0 → standard 2-parameter Weibull (recommended). If off, a 3-parameter fit frees the threshold via a constrained profile likelihood. Default: on. |
| Alpha | 1 − confidence level for the parameter intervals (0.05 → 95% CIs) Default: 0.05. |
How to read the card
The Results tab starts with what to know first (rows left out, checks that did not pass), then the interpretation in words and the Key Results; charts and assumption checks follow further down. Learn More explains the method in plain words. Read a Result Card covers all four tabs.
What it assumes
- Independence of observations
If it does not hold: If units do not fail independently from one common Weibull population (mixed failure modes), the single fitted shape/scale pair describes a blend that may not represent any real failure mode well.
How to check: Not checked by KernelStats: assumed from the study design; stated directly as a standing reminder. Mixed failure modes call for a per-mode (competing-risk) fit instead.
A worked example
38 shock absorbers on a durability test: 11 failed at recorded distances, 27 were still running (censored) when the test ended.
Result: Correct censored MLE: shape beta = 3.16, scale eta = 27,719 km. A naive fit using only the 11 observed failures (ignoring the 27 survivors): eta ~ 19,485 km, about 30% lower.
The censored analysis is the honest answer: the 27 surviving units are real evidence that the shock absorbers last longer than the 11 observed failures alone would suggest, and discarding that evidence would have significantly understated both the characteristic life and the B10 warranty metric derived from it.
From the Statistics Library.
The code tabs
Code gives this analysis as Python, R and MATLAB code (and SAS where the tab offers it), reading the data the way KernelStats did. Export sends the card to a report or to slides. See The Code tab.
Understand the statistics
Ask Oobi
Type one of these into Ask Oobi beside your data:
- Twenty pumps ran a 5,000-hour test; 7 failed and 13 were still running at test end. What are the Weibull parameters, the B10 life, and the reliability at 10,000 hours?
- Explain the censored Weibull reliability fit in plain words.
- What does Weibull distribution mean?
Last reviewed November 16, 2026.