When to use it
Before trusting capability indices or a control chart, you want to confirm your measurement system is good enough: each operator measures each part several times and you ask how much of the total variation is real part-to-part difference versus gauge/operator noise.
When not to: The parts sampled for the study do not span the real range of production (hand-picked near-identical parts will make PV collapse and %GRR look artificially bad regardless of gauge quality), replicates per operator-part cell number fewer than 2, or the design is not crossed (every operator measuring every part); a nested or other nonstandard design needs a different variance-decomposition model.
Step by step
Open it from the menu
Click Quality in the menu bar; under MSA choose Gage R&R (Measurement Systems Analysis).
Fill in the form
Choose the columns: What you measured (a number column), Parts measured, Operators. The form lists only columns whose type fits each field.
Check the options
The options start at their defaults: Study-variation multiplier, Pool Part × Operator interaction when p >, Lower spec limit (LSL), Upper spec limit (USL), Tolerance width (USL - LSL). Change one only when your question needs it.
Run the analysis
Press Run analysis. The Result Card opens on its Results tab.
What to choose in the form
| What you measured (a number column) Measurement required | One numeric column. The continuous quality characteristic being measured |
|---|---|
| Parts measured Part required | One categorical or ordered categorical column. The part / specimen identifier (each part measured by every operator) |
| Operators Operator required | One categorical or ordered categorical column. The operator / appraiser identifier |
| Study-variation multiplier | Std-dev multiplier for the study-variation spread (AIAG uses 6 for a ±3σ, 99.73% span; older studies use 5.15). Sets the absolute Study Variation column (k × SD); %Study Var. is a ratio, so it does not depend on k. Default: 6. |
| Pool Part × Operator interaction when p > | 'never' keeps the full crossed model. '0.05' (a common alpha-to-remove) or '0.25' (AIAG MSA manual) drop a non-significant interaction and pool it into the repeatability error. Default: never. |
| Lower spec limit (LSL) | Optional. With the upper limit, the card adds %Tolerance: each source's study variation (k x SD) as a percentage of USL - LSL. |
| Upper spec limit (USL) | Optional. With the lower limit, the card adds %Tolerance (P/T ratio). |
| Tolerance width (USL - LSL) | Optional, instead of the two limits: the width of the specification. Gives the same %Tolerance. |
How to read the card
The Results tab starts with what to know first (rows left out, checks that did not pass), then the interpretation in words and the Key Results; charts and assumption checks follow further down. Learn More explains the method in plain words. Read a Result Card covers all four tabs.
What it assumes
- Normality (of residuals, not of the raw data)
If it does not hold: Non-normal residuals make the ANOVA-based variance-component estimates (and therefore %GRR, %PV, and the number of distinct categories) less trustworthy.
How to check: Shapiro-Wilk on the model residuals (for 3 to 5000 residuals), reported directly on the card when computable.
A worked example
Five parts spanning the normal production range, each measured twice by three operators (30 total measurements).
Result: Repeatability (EV) is 62% of the GRR variance and reproducibility (AV) 38%; %GRR (study variation) = 18%, which means GRR is 3.2% of total variance and part variation 96.8%, so ndc = floor(1.41 x sqrt(96.8 / 3.2)) = 7.
The 18% %GRR falls in the marginal zone (acceptable depending on the application, cost, and risk, but worth improving before high-stakes use), while the ndc of 7 (above AIAG's threshold of 5) says the gauge can still separate the parts into several distinct groups; the two criteria do not always agree, and both belong in the report. Since repeatability dominates over reproducibility, the priority for improvement is the equipment itself rather than operator training.
From the Statistics Library.
The code tabs
Code gives this analysis as Python, R and MATLAB code (and SAS where the tab offers it), reading the data the way KernelStats did. Export sends the card to a report or to slides. See The Code tab.
Understand the statistics
Ask Oobi
Type one of these into Ask Oobi beside your data:
- Five parts are each measured twice by three operators: is the gauge reliable, and how many distinct categories can it resolve?
- Explain the Gage R&R (measurement systems analysis) in plain words.
- What does process capability index mean?
Last reviewed November 16, 2026.