Quality · Multivariate Charts

Hotelling T² Chart (Multivariate Control)

Hotelling T² control chart for two or more correlated quality characteristics monitored jointly: one chart, one false-alarm rate, sensitive to shifts no univariate chart can see.

In the menus Quality › Multivariate Charts › Hotelling T² Chart (Multivariate Control)

Also searched as hotelling hotelling t2 t squared chart multivariate control chart

When to use it

You monitor several correlated measurements (e.g. length AND diameter) and want a single chart that respects their correlation: separate X charts miss shifts that break the correlation structure and inflate the joint false-alarm rate.

When not to: A single measurement (there is nothing multivariate to correlate; use I-MR or X-bar charts), variables believed to be essentially uncorrelated with each other (separate univariate charts are simpler and equally valid), or when the covariance matrix is known or suspected to be unstable over time: T2's limits assume a fixed covariance structure, which this function cannot verify from a single dataset.

Step by step

  1. Open it from the menu

    Click Quality in the menu bar; under Multivariate Charts choose Hotelling T² Chart (Multivariate Control).

  2. Fill in the form

    Choose the columns: What you measured (two or more columns). The form lists only columns whose type fits each field.

  3. Check the options

    The options start at their defaults: Phase, False-alarm rate (α). Change one only when your question needs it.

  4. Run the analysis

    Press Run analysis. The Result Card opens on its Results tab.

What to choose in the form

Fields of the Hotelling T² Chart (Multivariate Control) form
What you measured (two or more columns) Variables requiredOne numeric column. Two or more correlated continuous measurements
Phase1 = retrospective (Beta limit, same data estimated the parameters); 2 = monitoring limit for future observations (F-based). Default: 1.
False-alarm rate (α)Per-point false-alarm probability (0.0027 ≈ the 3σ Shewhart convention). Default: 0.0027.

How to read the card

The Results tab starts with what to know first (rows left out, checks that did not pass), then the interpretation in words and the Key Results; charts and assumption checks follow further down. Learn More explains the method in plain words. Read a Result Card covers all four tabs.

What it assumes

Normality (of residuals, not of the raw data)

If it does not hold: Hotelling's T-squared limits are derived assuming the variables jointly follow a multivariate normal distribution; non-normal marginals (and, more broadly, non-normal joint structure this check cannot fully see) distort the true false-alarm rate of the chart.

How to check: Shapiro-Wilk on each variable's marginal distribution, Bonferroni-adjusted across variables and reported as the worst (smallest-p) variable on the card; this is necessary for joint multivariate normality but not sufficient for it, and is reported as not testable on a short series or a zero-variance variable.

Independence of observations

If it does not hold: T-squared's control limits assume the observations are independent over time; autocorrelation narrows or widens the true spread of T-squared away from its nominal distribution, manufacturing false alarms or masking real ones.

How to check: Ljung-Box lag-1 test on each variable, Bonferroni-adjusted across variables and reported as the worst (smallest-p) variable on the card; reported as not testable on a short series or a zero-variance variable.

A worked example

Three correlated dimensional measurements on 40 manufactured parts (Phase I, alpha = 0.0027), with an injected out-of-control shift at part 30.

Result: Phase I UCL = 12.2303; the T2 value at part 30 is 28.84, well above the limit, with 'diameter B' flagged as the largest individual contributor to that signal.

Part 30 shows a genuine joint departure from the multivariate norm that a well-tuned set of separate univariate charts might have missed if it manifested mainly as a correlation break rather than a large shift in any single measurement; diameter B is the most promising variable to investigate first, though a full attribution analysis would confirm it.

From the Statistics Library.

The code tabs

Code gives this analysis as Python, R and MATLAB code (and SAS where the tab offers it), reading the data the way KernelStats did. Export sends the card to a report or to slides. See The Code tab.

Understand the statistics

Ask Oobi

Type one of these into Ask Oobi beside your data:

  • Are bearing inner AND outer diameters jointly in control, including their correlation?
  • Explain the Hotelling T² chart (multivariate control chart) in plain words.
  • What does normality (of residuals, not of the raw data) mean?

Last reviewed November 16, 2026.

Report an unclear step