Understand the idea
Some processes only give you one reading at a time (daily fill weight, one measurement per batch), so there is no small group of readings to average together the way an X-bar chart does. The I-MR chart is built for exactly that situation: the top panel (the I chart) plots each individual reading directly, and the bottom panel (the MR chart) plots how much each reading differs from the one right before it, the 'moving range', which is the chart's stand-in for short-term process spread.
A point beyond the control limits on the I chart, or a run of eight readings in a row on the same side of the center line, flags a likely special cause worth investigating: something changed, rather than ordinary random noise. The MR chart only uses the beyond-limits rule, never the run-of-8 rule, because consecutive moving ranges always share one of their two readings and are therefore correlated with each other by construction; a run-of-8 test there would trigger far too often even when nothing is wrong.
An easy trap: the very first chart you build is a TRIAL chart, not the final answer. Its limits are computed from the same data they are judging, so if that data happens to include a genuine problem point, that point can drag the average and widen the limits enough to hide smaller, real issues or to manufacture a false run. The standard fix is to find and remove any assignable-cause points, recompute the limits from what remains, and only then use those cleaned-up limits to monitor future production.
An I-MR chart is an individuals and moving range chart, also called an XmR chart: the individuals control chart plots each single value, and the moving range chart plots the difference between each value and the one before.
Practitioner explanation
KernelStats computes MR_i = |x_i - x_{i-1}| (n-1 ranges), sigma-hat = MRbar/d2 with d2 = 1.128 (the n=2 constant, since a moving range always spans exactly two points), I-chart limits x-bar +/- 3*sigma-hat, and MR-chart limits CL = MRbar, UCL = D4*MRbar = 3.267*MRbar, LCL = 0 (D3 = 0 at n=2). A blank or non-numeric row breaks adjacency: the two readings on either side of a gap are explicitly NOT treated as a valid two-point moving range and that pair is skipped rather than spliced in; splicing a multi-step gap into a single moving range would understate how many steps actually elapsed and inflate sigma-hat, MRbar, and every derived limit. The card reports exactly how many rows were dropped and how many ranges were skipped at gaps, and labels every point by its ORIGINAL table row so a flagged point maps directly to the row an operator would open.
Only Rule 1 (a point beyond the 3-sigma limit) and Rule 2 (eight consecutive points on one side of the center line) are applied, on the I panel only; the MR panel uses Rule 1 alone, since moving ranges are serially correlated by construction and a run rule there would be spurious. KernelStats deliberately does not implement the full Western Electric/Nelson rule set (zone rules, trends, stratification, and similar) here: a clean chart means 'no Rule-1 or Rule-2 signal', not 'no pattern of any kind', and this is stated honestly rather than implied to be exhaustive.
Independence is TESTED, not merely assumed: the card reports lag-1 autocorrelation with a Ljung-Box Q(1) test and warns when the series shows significant dependence, because positive autocorrelation makes the 3-sigma limits too tight (manufacturing false special-cause signals) while negative autocorrelation makes them too wide (hiding real ones). Because the very first chart's limits are computed from the same data being judged, KernelStats's Learn More content explicitly documents the standard Phase I procedure (find and remove assignable-cause points, recompute, repeat until what remains is in control) but does not automate that iterative cleaning itself; it is a workflow the analyst carries out using the reported out-of-control points.
When to use it
Consider it when
You measure one unit at a time with no natural way to form rational subgroups (a batch process, a daily reading, a one-at-a-time inspection), and want to monitor whether the process mean and short-term variation are stable.
Use caution when
When you CAN form rational subgroups of several readings taken close together in time: use an X-bar/R or X-bar/S chart instead, which is more sensitive to mean shifts because it charts subgroup averages rather than single noisy readings. Also avoid trusting the very first (trial) chart's limits as final: they are contaminated by whatever assignable causes are already in the reference data.
Formulas and symbols
Estimated process sigma from the moving range
d2 is the bias-correction constant for a range of n=2 consecutive points, since each moving range spans exactly two readings.
Individuals (I) chart limits
x-bar the mean of the individual readings.
Moving range (MR) chart limits
D4 = 3.267 and D3 = 0 are the standard SPC constants for a subgroup/range size of n=2.
Assumptions and checks
- Independence of observations. Autocorrelated data make the individuals-chart limits wrong: positive autocorrelation makes the moving ranges small relative to the real spread, so sigma-hat is too small, the limits too tight and false alarms multiply, while negative autocorrelation inflates the moving ranges, widening the limits and masking real signals.
In KernelStats: Ljung-Box lag-1 test on the individual observations, reported directly on the card as an 'Independence & rational ordering' check; not testable on fewer than 8 points or a zero-variance series, which the card states honestly rather than fabricating a verdict.
- Normality (of residuals, not of the raw data). Individuals-chart limits (x-bar +/- 3 sigma-hat from the average moving range) assume the individual values are roughly normal; skewed or heavy-tailed data make the true false-alarm rate differ from the nominal ~0.27%, in either direction.
In KernelStats: Not checked by KernelStats: no normality test is run on the individual values; the Learn More content states the assumption directly; run Normality Test (Battery) on the readings to check it.
Alternatives
- X̄-R Chart (Means & Ranges). Readings can be grouped into rational subgroups of roughly 2-10 units taken close together in time, giving a more sensitive and standard chart than plotting single individuals.
- EWMA Chart (Exponentially Weighted Moving Average). The concern is a SMALL, sustained shift (roughly 0.5-1.5 sigma) that an individuals chart would be slow to detect.
- CUSUM Chart (Tabular Cumulative Sum). You want the fastest classic detector of a specific, pre-chosen small sustained shift size, with an estimate of exactly when it began.
Worked example
Scenario
25 consecutive daily fill-weight readings, with a deliberate spike at reading 20.
Result
x-bar = 250.3640, sigma-hat = 0.8533 (MRbar = 0.9625), I-chart limits [247.8042, 252.9238], MR-chart UCL = 3.1445; reading 20 breaches the I-chart UCL, and the moving ranges spanning readings 19-20 and 20-21 both breach the MR-chart UCL.
Interpretation
The spike at reading 20 is flagged on both panels (an unusually high individual value AND an unusually large jump to get there), which is exactly the joint signature of a genuine special-cause event rather than ordinary process noise. Before trusting these limits for future monitoring, the standard practice is to investigate reading 20's cause, remove it if assignable, and recompute.
Common misconceptions
Misconception
A point inside the I-MR chart's control limits means that unit meets the customer's specification.
Correction
The control limits are built entirely from the process's OWN variation (sigma-hat estimated from the moving range): they describe what the process typically does, not a specification a customer or engineer set. A stable, in-control process can still be producing units outside spec; comparing to a specification is a capability study's job (Cp/Cpk), not the control chart's.
Read more: Misconception: control limits and specification limits are the same thing
Misconception
The limits from the very first I-MR chart you build are the final limits to use for ongoing monitoring.
Correction
Phase I limits are computed from the SAME data they are judging, so any assignable-cause point already in that data pulls the mean toward itself and widens the moving-range-based limits, potentially hiding smaller real signals or manufacturing a spurious run. The standard practice is to identify and remove out-of-control points with a known cause, recompute the limits from what remains, and repeat until the retained data is in control; only THOSE final limits should be carried forward to monitor future production.
References
- NIST/SEMATECH e-Handbook of Statistical Methods, §6.3.2.1 Individuals control charts, NIST/SEMATECH (2012), §6.3.2.1.
- Introduction to Statistical Quality Control, Montgomery, D. C. (2019), §6.4.