Understand the idea
Before you run an experiment, you often have more than one reasonable plan on the table: a smaller, cheaper design versus a bigger, more thorough one. Looking at each design's evaluation card one at a time makes the trade-off hard to see. This tool runs the same evaluation over every candidate and lines the results up together: how many runs each needs, how cleanly it can separate effects from each other (aliasing), how efficiently it uses its runs (D-efficiency), and how likely it is to actually detect the effect size you care about (power).
The recommendation follows a simple, honest logic called Pareto-optimality: a design is only worth ruling out if some OTHER design beats it on every dimension at once (no more runs, no worse efficiency, no worse power) while being strictly better on at least one. Among whatever candidates survive that filter, the tool prefers the smallest one that still clears reasonable efficiency and power thresholds.
One thing this tool deliberately does NOT decide for you: whether a particular design's aliasing pattern is actually a problem. A design with more aliased effect pairs might still be exactly the right choice if you have already decided those particular terms are not ones you plan to interpret separately. Read the aliasing column together with your own model of interest, not as a standalone verdict.
A DOE design comparison lets you compare designs side by side: a design trade-off table lists each candidate's number of runs, its efficiency and its power.
Practitioner explanation
Comparing designs works on several candidate design tables at once, so it has its own command in the DOE menu instead of the ordinary single-table analysis form.
Pareto-optimality here is defined strictly: design A dominates design B when A uses no more runs, has no worse D-efficiency, and has no worse power, with at least one of the three STRICTLY better. A design that no other candidate dominates is Pareto-optimal, and the recommendation is drawn from that set, preferring the fewest runs among candidates that also clear a D-efficiency threshold of 90% and a power threshold of 80% when at least one candidate reaches both.
The comparison reuses the SAME per-design evaluation engine that powers the standalone 'Evaluate a design' card (resolution, aliasing grade, D-efficiency, condition number, and power for a stated effect size and alpha), so a design's numbers here are identical to what its own individual evaluation card would report; this tool adds the trade-off framing and the recommendation logic, not a different underlying calculation.
When to use it
Consider it when
Two or more candidate designs have already been generated or imported for the same experiment, and the choice between them needs to weigh runs against aliasing, efficiency, and power together rather than reading each design's evaluation card in isolation.
Use caution when
Only a single design is under consideration (use the standalone design-evaluation card instead), or the comparison is attempted through the ordinary single-table Run panel; this function's execute() path refuses that route by design and must be reached through the dedicated multi-table DOE comparison endpoint.
Formulas and symbols
Pareto dominance
A design is Pareto-optimal when no other candidate dominates it on all three of runs, D-efficiency, and power.
D-efficiency
A relative measure (0-100%) of how efficiently a design's run matrix X estimates its p model parameters compared to a theoretically ideal design of the same size n.
Assumptions and checks
- This method compares CANDIDATE designs on their theoretical properties (resolution, aliasing structure, power) computed from the design matrix alone; it does not run on any collected data, so nothing here can detect a real experiment's actual noise, non-normality, or a factor that turns out to matter more than assumed.
In KernelStats: Not applicable: there is no data to check assumptions against at the design-comparison stage. Once an experiment is run, use Design of Experiments (2-Level Factorial) (or the appropriate DOE analysis) on the actual results, which does check residual normality.
- The reported power and aliasing comparisons assume the analyst's stated effect size and alpha are realistic for the actual study; an optimistic assumed effect size makes every candidate design look more capable than it will be in practice.
In KernelStats: Not checked by KernelStats: the effect size and alpha are required inputs the analyst supplies and are not validated against any prior data.
Alternatives
- Design of Experiments (2-Level Factorial). The experiment has already been run and the question is now about analyzing the collected data, not choosing between candidate designs beforehand.
- DOE Power Simulation (Monte Carlo). You want to explore how power for a single design changes across a range of possible effect sizes or sample sizes, rather than compare several already-specified candidate designs against each other.
Worked example
Scenario
Choosing between a 16-run resolution-IV 2^(6-2) fraction and a 32-run resolution-VI 2^(6-1) fraction for a 6-factor screening experiment, compared under a main-effects model.
Result
Both are orthogonal two-level designs, so both reach 100% D-efficiency for the main-effects model; the 32-run design has higher minimum power, and the 16-run design's two-factor interactions are aliased with one another in chains (main effects stay clear of them). Neither design dominates (fewer runs on one side, more power on the other), so both are Pareto-optimal, and when the 16-run design's minimum power also clears 80% the tool recommends it as the smallest design meeting both the 90% efficiency and 80% power bars.
Interpretation
The recommendation is not simply 'bigger is safer': the smaller design already meets the stated adequacy bars, and the aliased pairs are worth checking against which specific interactions the analyst actually plans to interpret before finalizing the choice.
Common misconceptions
Misconception
The design with the most aliased effect pairs is automatically the wrong choice.
Correction
Aliasing only matters for the SPECIFIC effects you actually plan to interpret. A design with more aliased pairs can still be the right, more economical choice if those particular aliased terms are ones the analyst has already decided not to interpret separately. The aliasing column needs to be read against the analyst's own model of interest, not treated as an automatic disqualifier.
Misconception
The Pareto-optimal design set will always contain exactly one clear winner.
Correction
Pareto-optimality can leave MULTIPLE designs in the running when none dominates the others on every dimension at once: a smaller design with slightly lower power and a larger design with slightly higher power can both be Pareto-optimal simultaneously. The tool's recommendation picks the smallest design among the Pareto-optimal set that clears reasonable efficiency and power thresholds, but that is a preference rule layered on top of Pareto-optimality, not something Pareto-optimality alone determines.
References
- Design and Analysis of Experiments, Montgomery, D. C. (2019).
- Response Surface Methodology: Process and Product Optimization Using Designed Experiments, Myers, R. H., Montgomery, D. C. and Anderson-Cook, C. M. (2016).