Quality · Attributes Charts

c-Chart (Defect Count)

Control chart for the count of defects per inspection unit when the inspection area is constant.

In the menus Quality › Attributes Charts › c-Chart (Defect Count)

Also searched as c chart defects chart count of defects chart

When to use it

You count the number of defects (not defective items) on each unit, and every unit has the same inspection area/opportunity.

When not to: When the inspection area or opportunity varies between units (use a u-chart, which normalizes by area), when you are counting defective ITEMS (pass/fail) rather than the number of defects on each item (use a p- or np-chart), or when defect counts are severely overdispersed relative to Poisson (variance far exceeding the mean), which this chart does not test for and will understate the true control limits if present.

Step by step

  1. Open it from the menu

    Click Quality in the menu bar; under Attributes Charts choose c-Chart (Defect Count).

  2. Fill in the form

    Choose the columns: Defects counted. The form lists only columns whose type fits each field.

  3. Run the analysis

    Press Run analysis. The Result Card opens on its Results tab.

What to choose in the form

Fields of the c-Chart (Defect Count) form
Defects counted Defects requiredOne numeric column. Count of defects on each inspection unit

How to read the card

The Results tab starts with what to know first (rows left out, checks that did not pass), then the interpretation in words and the Key Results; charts and assumption checks follow further down. Learn More explains the method in plain words. Read a Result Card covers all four tabs.

A worked example

Surface blemish counts recorded on 30 consecutively painted panels, each panel offering the same inspection area.

Result: c-bar = 4.2, UCL = 10.35, LCL = 0 (floored, since c-bar is below 9); one panel with 12 blemishes falls above the UCL. Because c-bar is below 5 the card marks the normal approximation as not met and reports the exact Poisson false-alarm rate of these limits, about 0.41% per point rather than the nominal 0.27%.

The blemish rate is stable at roughly 4 per panel except for one out-of-control panel, which should be investigated for an assignable cause (a paint-line disruption, a batch of contaminated material) rather than treated as ordinary random variation.

From the Statistics Library.

The code tabs

Code gives this analysis as Python, R and MATLAB code (and SAS where the tab offers it), reading the data the way KernelStats did. Export sends the card to a report or to slides. See The Code tab.

Understand the statistics

Ask Oobi

Type one of these into Ask Oobi beside your data:

  • Is the number of surface blemishes per painted panel stable over the production run?
  • Explain the c-Chart (defect count control chart) in plain words.
  • What does Poisson distribution mean?

Last reviewed November 16, 2026.

Report an unclear step