Concept · Statistics Library

Control limits

Control limits are the statistically-derived boundaries on a control chart, typically three standard deviations of the plotted statistic above and below its center line, used to flag when a process has likely shifted rather than merely shown its ordinary random variation.

Chapter 6: Quality, processes and timeReading 6.1

Understand the idea

Every process has natural, expected wobble even when nothing has gone wrong: no two parts are ever identical to the micron. Control limits mark the boundary between that ordinary wobble and a signal worth investigating: a point beyond the limits is unlikely to have happened by chance alone if the process is behaving as it has been.

They are computed FROM the process's own observed variation (typically plus or minus three standard deviations of the charted statistic around its center line), not set by a customer requirement or an engineering target. That is the single most important thing to get right about them.

A point outside the control limits, or a run of points showing a non-random pattern (several points trending in one direction, or several in a row on the same side of the center line), signals that something changed in the process, worth investigating, not that a defective part was necessarily produced.

Because the limits sit three standard deviations from the center line, they are often called 3-sigma limits. The upper line is the upper control limit (UCL) and the lower line is the lower control limit (LCL). A control chart with a center line and control limits like these is also called a Shewhart chart, after Walter Shewhart, who invented it. The pattern rules, such as several points in a row on one side of the center line, are often called the Western Electric rules.

Practitioner explanation

For a Shewhart chart the 3-sigma limits are UCL/LCL = center-line +/- 3 * sigma_hat(statistic), where sigma_hat is estimated from the SAME in-control data (via R-bar/d2 for an X-bar & R chart, moving-range/d2 for individuals charts, or the relevant closed-form variance for attributes charts), never from a specification. Using a specification limit in place of a control limit is one of the most consequential and common errors in SPC practice.

The 3-sigma choice trades a low false-alarm rate (about 0.27% per point under normality) against detection speed for small shifts; supplementary run rules (a Western Electric rule such as one point beyond 3-sigma, or two of three beyond 2-sigma on the same side) catch smaller, sustained shifts the 3-sigma limit alone would miss, at the cost of a higher combined false-alarm rate. KernelStats deliberately applies only Rule 1 (a point beyond the limits) and, on the individuals and X-bar panels, Rule 2 (eight in a row on one side); the zone rules are not implemented, so a clean chart means 'no Rule-1 or Rule-2 signal', not 'no pattern of any kind'.

KernelStats computes control limits per chart type (X-bar/R, X-bar/S, individuals/moving-range, and the attributes charts p/np/c/u with their variants) from the plotted subgroup data itself, flags rule violations directly on the chart (Rule 1 on every chart; Rule 2 on the individuals and X-bar panels only: range, S, moving-range and attribute charts use Rule 1 alone), and keeps control limits and specification limits (used separately by the process capability analysis) visually and numerically distinct on the card.

When to use it

Consider it when

To monitor a process over time and distinguish routine variation from a genuine shift that needs investigating.

Use caution when

Never in place of specification limits when judging whether individual parts meet a customer or engineering requirement; control limits describe the PROCESS's own behavior, specification limits describe what is acceptable to the customer, and the two are frequently at different distances from the center.

Formulas and symbols

3-sigma upper control limit (X-bar chart)

UCLxˉ=xˉˉ+A2RˉUCL_{\bar{x}} = \bar{\bar{x}} + A_2 \bar{R}

x-double-bar is the grand mean of subgroup means, R-bar the mean subgroup range, A_2 a tabulated constant depending on subgroup size.

3-sigma lower control limit (X-bar chart)

LCLxˉ=xˉˉ−A2RˉLCL_{\bar{x}} = \bar{\bar{x}} - A_2 \bar{R}

Same quantities as the upper limit, subtracted rather than added.

Common misconceptions

Misconception

Control limits are the same as specification limits, just computed automatically.

Correction

Control limits come from the process's own observed variation and answer 'has the process changed'. Specification limits come from engineering or customer requirements and answer 'is this part acceptable'. A process can be perfectly in statistical control while still producing parts outside the specification limits, if the process is not capable.

Read more: Misconception: control limits and specification limits are the same thing

References

  1. NIST/SEMATECH e-Handbook of Statistical Methods, §6.3.2 What are Variables Control Charts?, NIST/SEMATECH (2012), §6.3.2.