Method · Statistics Library

c-Chart (defect count control chart)

A c-chart tracks the count of defects per inspection unit over time, using flat control limits built from the Poisson distribution (where the variance equals the mean), to flag when the process's defect rate has shifted.

Topic indexA reference reading outside the guided chapter sequence

Understand the idea

Picture inspecting painted panels for scratches. Some panels have none, some have a few, and a panel COULD have several scratches even though it is still 'one unit'. That is a count of DEFECTS, not a pass/fail count of defective units, and it is exactly what a c-chart is built for.

Because you are counting rare, independent events over a fixed opportunity (one panel each time), the Poisson distribution describes how much the count should naturally bounce around even when nothing has changed, and the Poisson distribution has a special property: its spread (variance) is mathematically tied to its average. That lets the chart compute control limits directly from the average defect count, with no separate spread measurement needed.

A point beyond the limits says the defect RATE has shifted from its usual pattern; it does not say the panels meet or fail any quality specification. Control limits describe what the process itself typically does, not a customer's requirement.

A c-chart is a defect count chart, also called a count of defects chart: it tracks the number of defects in units of a fixed size, and it is a Poisson control chart because its limits come from the Poisson distribution.

Practitioner explanation

The center line is c-bar (the mean defect count per unit) and the limits are flat: UCL/LCL = c-bar +/- 3*sqrt(c-bar), using the Poisson property that variance equals the mean; no separate variance estimate (no moving range, no subgroup range) is computed or needed. LCL is floored at 0 since a negative defect count is impossible. The limits are FLAT specifically because the inspection area/opportunity is assumed constant across every unit; when the area of opportunity varies from unit to unit, a u-chart (defects per unit area) is the correct chart, not this one, because c-chart limits would be wrong for a varying denominator.

KernelStats does not test whether the Poisson assumption itself holds (no dispersion test, e.g. for overdispersion relative to Poisson); it is applied by convention for defect-count data, consistent with standard SPC practice. What the card does check: counts must be non-negative and at least 2 inspection units are required (both refused otherwise), non-integer counts draw a warning, and the validity of the 3-sigma limits is assessed by computing the EXACT Poisson false-alarm rate of the limits actually drawn and publishing it next to c-bar; when c-bar is below 5 and that rate is well above nominal, the out-of-control verdict is softened rather than stated flatly.

Because this chart has no comparison to a specification and issues no statistical hypothesis test, out-of-control detection here is the beyond-limits (3-sigma) rule only; KernelStats does not apply the Western Electric run rules (2-of-3, 4-of-5, and similar) to attributes charts the way it does to some variables charts, so a subtler sustained shift that never breaches 3 sigma will not be flagged by this card.

When to use it

Consider it when

You count the number of defects (not defective/non-defective units) found on each inspection unit, and every unit offers the same, constant area of opportunity for a defect to occur.

Use caution when

When the inspection area or opportunity varies between units (use a u-chart, which normalizes by area), when you are counting defective ITEMS (pass/fail) rather than the number of defects on each item (use a p- or np-chart), or when defect counts are severely overdispersed relative to Poisson (variance far exceeding the mean), which this chart does not test for and will understate the true control limits if present.

Formulas and symbols

Center line and control limits

cˉ=mean defects per unit,UCL/LCL=cˉ±3cˉ\bar c = \text{mean defects per unit}, \qquad UCL/LCL = \bar c \pm 3\sqrt{\bar c}

The Poisson distribution's variance equals its mean, so the standard deviation used for the 3-sigma limits is simply sqrt(c-bar); LCL is floored at 0.

Upper control limit

UCL=cˉ+3cˉUCL = \bar c + 3\sqrt{\bar c}

The threshold beyond which a defect count signals a shift from the process's stable Poisson pattern.

Assumptions and checks

  • When c-bar (the average defect count) is below about 5, the normal-curve approximation behind the 3-sigma limits breaks down, and once c-bar falls to 9 or below the lower limit is pinned at 0, meaning an improvement in the defect rate can never signal on this chart.

    In KernelStats: Checked directly: the card reports the 'Normal approximation to the Poisson' check as failed below c-bar = 5, and separately notes whenever the LCL is pinned at 0.

Alternatives

  • u-Chart (Defects per Unit). The inspection area or opportunity for a defect varies from unit to unit: track defects PER UNIT AREA instead of the raw count.
  • np-Chart (Number Nonconforming). You are counting defective ITEMS (each unit is simply pass or fail) with a constant sample size, rather than counting multiple possible defects per unit.
  • p-Chart (Fraction Nonconforming). You are counting the fraction (or count) of defective items and the sample size varies from period to period.

Worked example

Scenario

Surface blemish counts recorded on 30 consecutively painted panels, each panel offering the same inspection area.

Result

c-bar = 4.2, UCL = 10.35, LCL = 0 (floored, since c-bar is below 9); one panel with 12 blemishes falls above the UCL. Because c-bar is below 5 the card marks the normal approximation as not met and reports the exact Poisson false-alarm rate of these limits, about 0.41% per point rather than the nominal 0.27%.

Interpretation

The blemish rate is stable at roughly 4 per panel except for one out-of-control panel, which should be investigated for an assignable cause (a paint-line disruption, a batch of contaminated material) rather than treated as ordinary random variation.

Common misconceptions

Misconception

A point that falls inside the c-chart's control limits means those units meet the customer's quality specification.

Correction

Control limits are computed from the process's OWN historical Poisson variation around its own average defect count: they describe what the process typically does, not a specification or tolerance. A stable, in-control process can still be shipping more defects per unit than a customer will accept; capability against a specification is a separate question from statistical control.

Read more: Misconception: control limits and specification limits are the same thing

Misconception

Defect COUNTS and defective ITEM counts are basically the same thing and either chart works for either kind of data.

Correction

A c-chart counts DEFECTS, where one unit can have several (three scratches on one panel). A p- or np-chart counts DEFECTIVE ITEMS, where a unit is simply classified pass or fail regardless of how many things are wrong with it. Using the wrong chart for the kind of count you actually recorded uses the wrong variance model and produces the wrong control limits.

References

  1. NIST/SEMATECH e-Handbook of Statistical Methods, §6.3.3.2 Counts control charts, NIST/SEMATECH (2012), §6.3.3.2.
  2. Introduction to Statistical Quality Control, Montgomery, D. C. (2019).