Quality · Variables Charts

I-MR Chart (Individuals & Moving Range)

Individuals (I) and Moving-Range (MR) control charts for a single continuous measurement taken one unit at a time.

In the menus Quality › Variables Charts › I-MR Chart (Individuals & Moving Range)

Also searched as control chart spc statistical process control shewhart shewhart chart individuals chart i chart i-mr

When to use it

You measure one unit at a time (no natural subgroups) and want to monitor whether the process mean and short-term variation are stable.

When not to: When you CAN form rational subgroups of several readings taken close together in time: use an X-bar/R or X-bar/S chart instead, which is more sensitive to mean shifts because it charts subgroup averages rather than single noisy readings. Also avoid trusting the very first (trial) chart's limits as final: they are contaminated by whatever assignable causes are already in the reference data.

Step by step

  1. Open it from the menu

    Click Quality in the menu bar; under Variables Charts choose I-MR Chart (Individuals & Moving Range).

  2. Fill in the form

    Choose the columns: What you measured (a number column). The form lists only columns whose type fits each field.

  3. Run the analysis

    Press Run analysis. The Result Card opens on its Results tab.

What to choose in the form

Fields of the I-MR Chart (Individuals & Moving Range) form
What you measured (a number column) Measurement requiredOne numeric column. The continuous measurement, in time order

How to read the card

The Results tab starts with what to know first (rows left out, checks that did not pass), then the interpretation in words and the Key Results; charts and assumption checks follow further down. Learn More explains the method in plain words. Read a Result Card covers all four tabs.

What it assumes

Independence of observations

If it does not hold: Autocorrelated data make the individuals-chart limits wrong: positive autocorrelation makes the moving ranges small relative to the real spread, so sigma-hat is too small, the limits too tight and false alarms multiply, while negative autocorrelation inflates the moving ranges, widening the limits and masking real signals.

How to check: Ljung-Box lag-1 test on the individual observations, reported directly on the card as an 'Independence & rational ordering' check; not testable on fewer than 8 points or a zero-variance series, which the card states honestly rather than fabricating a verdict.

Normality (of residuals, not of the raw data)

If it does not hold: Individuals-chart limits (x-bar +/- 3 sigma-hat from the average moving range) assume the individual values are roughly normal; skewed or heavy-tailed data make the true false-alarm rate differ from the nominal ~0.27%, in either direction.

How to check: Not checked by KernelStats: no normality test is run on the individual values; the Learn More content states the assumption directly; run Normality Test (Battery) on the readings to check it.

A worked example

25 consecutive daily fill-weight readings, with a deliberate spike at reading 20.

Result: x-bar = 250.3640, sigma-hat = 0.8533 (MRbar = 0.9625), I-chart limits [247.8042, 252.9238], MR-chart UCL = 3.1445; reading 20 breaches the I-chart UCL, and the moving ranges spanning readings 19-20 and 20-21 both breach the MR-chart UCL.

The spike at reading 20 is flagged on both panels (an unusually high individual value AND an unusually large jump to get there), which is exactly the joint signature of a genuine special-cause event rather than ordinary process noise. Before trusting these limits for future monitoring, the standard practice is to investigate reading 20's cause, remove it if assignable, and recompute.

From the Statistics Library.

The code tabs

Code gives this analysis as Python, R and MATLAB code (and SAS where the tab offers it), reading the data the way KernelStats did. Export sends the card to a report or to slides. See The Code tab.

Understand the statistics

Ask Oobi

Type one of these into Ask Oobi beside your data:

  • Is my daily fill-weight reading staying within statistical control?
  • Explain the I-MR chart (individuals and moving range) in plain words.
  • What does no (residual) autocorrelation mean?

Last reviewed November 16, 2026.

Report an unclear step